Questions and Answers

  • M
    Mr. Matthew Rodriguez DDSAug 16, 2025
    What to do if I have BUS-OFF error (many communication errors occurred) on Lenze DC Drives?
    • M
      Ms. Heather Bailey DVMAug 17, 2025
      If you're getting a BUS-OFF error on your Lenze DC Drives, it means the Drive PLC has received too many incorrect telegrams via the system bus and has been disconnected. Check whether a bus terminator is available, shield the control cables, check the PE connection, and if necessary, reduce the baud rate to address this issue.
  • S
    Stephen PhillipsAug 19, 2025
    What causes system error in Lenze EPL 10201-EI?
    • B
      Brian HurleySep 12, 2025
      A system error in Lenze DC Drives can be caused by strong interference on control cables, in which case you should shield the control cables. Another potential cause is ground or earth loops in the wiring.
  • S
    sean84Aug 22, 2025
    What causes external fault (TRIP-Set) in Lenze DC Drives?
    • C
      Chase RussellAug 22, 2025
      An external fault (TRIP-Set) in Lenze DC Drives occurs when a digital signal assigned to TRIP set has been activated. To solve this, check the external encoder.
  • C
    Curtis GonzalezAug 25, 2025
    What causes communication error to AIF in Lenze EPL 10201-EI?
    • R
      robertsthomasAug 25, 2025
      A communication error to AIF in Lenze DC Drives is caused by faulty transmission of control commands via AIF. To resolve this, insert the communication module into the hand terminal.
  • D
    Deanna EllisAug 27, 2025
    What causes communication error to CAN-IN2 on Lenze EPL 10201-EI?
    • I
      Isaiah OsborneAug 27, 2025
      A communication error to CAN-IN2 on Lenze DC Drives occurs when the CAN-IN2-object receives faulty data or communication is interrupted. Ensure plug-in connection - bus module, check FIF, check transmitter, and increase monitoring time under C0357/2 if necessary.
  • C
    Casey AndersonAug 30, 2025
    What causes communication error to CAN-IN1 with event or time control on Lenze EPL 10201-EI?
    • J
      Julie FitzgeraldAug 30, 2025
      A communication error to CAN-IN1 with event or time control on Lenze DC Drives happens when the CAN-IN1-object receives faulty data or communication is interrupted. Ensure plug-in connection - bus module, check FIF, check transmitter, and increase monitoring time under C0357/3 if necessary.
  • R
    robert05Sep 2, 2025
    What to do if my Lenze EPL 10201-EI PC does not respond?
    • Y
      Yvette EdwardsSep 2, 2025
      If your PC isn't responding when using Lenze DC Drives, it might be because the system-bus module was disconnected from the parallel port (LPT) of the PC during operation; try restarting the PC. Another cause could be that a print job was sent to the interface/port used by the system-bus module. If this is the case, restart the PC and use the other parallel port (LPT) for printing.
  • J
    Jon ThomasSep 5, 2025
    What to do if there is no control signal on the digital outputs (X2) of Lenze EPL 10201-EI?
    • C
      Carlos ConradSep 5, 2025
      If there's no control signal on the digital outputs (X2) of your Lenze DC Drives, it could be due to a missing connection between X1/+24 and X1/O24. Set up the connection.
  • J
    Jacob FrankSep 7, 2025
    What causes faulty transfer of PAR1 with keypad/PC in Lenze EPL 10201-EI DC Drives?
    • M
      Mario PhamSep 7, 2025
      Faulty transfer of PAR1 with keypad/PC in Lenze DC Drives is due to a defective PAR1. To resolve this, repeat the data transfer or load the Lenze setting.
  • M
    Megan BlackSep 10, 2025
    What causes initialisation error during transfer of parameter set in Lenze EPL 10201-EI?
    • E
      Edward GriffithSep 12, 2025
      An initialisation error during the transfer of the parameter set in Lenze DC Drives is caused by a fault detected during the transfer of the parameter set to the Drive PLC, or the parameter set does not match the Drive PLC. Correct the parameter set to solve this.

Summary

Safety information

Electrical connection

Details permissible DC voltage range and restrictions on mains circuits.

Installation according to EMC

System bus (CAN) wiring

Commissioning

Troubleshooting and fault elimination

Faulty behaviour of the Drive PLC

Lists malfunctions, their causes, and remedies.

System error messages

Details error codes, causes, and remedies for system errors.

Lenze EPL 10201-EI Specifications

General IconGeneral
BrandLenze
ModelEPL 10201-EI
CategoryDC Drives
LanguageEnglish