Loading...
Handling of lockable manual release lever
NOTICE
Only lock the hand release in the service posion for service work!
The manual release must not be locked in the service posion during operaon, otherwise
the brake could be damaged!
Always secure the terminal block against loosening in every posion with cheese head
screw and nut!
Operang posion, brake is not released Service posion, brake is released
1 4
3
51.1
1 Cheese head screw with hexagon nut 4 Manual release lever
3 Terminal block 5 Fan cover
How to lock the manual release lever:
1.
Loosen hexagon nut (1.1) and cheese head screw (1).
2.
Pull the terminal block (3) out of the slot in the fan cover and turn it by 180 .
3.
Actuate the manual release lever (4) and bring it into the service posion, pushing the
terminal block (3) under slight pressure into the slot of the fan cover (5).
4.
Tighten the cheese head screw (1) to the specied torque and counter with hexagon head
screw (1.1).
Mechanical installaon
Mounng
Product extensions