EasyManua.ls Logo

Lenze g500-S Series - Commissioning; Important Notes

Lenze g500-S Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
Important notes
Temperature ranges
The following temperature ranges are available matched to your ambient condions:
Default
Deep-freeze
Wide range
Check the ambient temperature and lubricant shown on the nameplate.
4Nameplates ^ 12
Pay aenon to the notes on the temperature ranges!
Temperature ranges
Standard
Ambient temperature 0 °C … +40 °C
Lubricant Mineral oil
CLP 460
Synthec oil
CLP HC 220
Food-compable oil
CLP HC 220 USDA H1
Note At an ambient temperature generally over +30 °C:
The applicaon case must be checked by Lenze.
Low-temperature
Ambient temperature -30 °C … +10 °C
Lubricant Food-compable oil
CLP HC 46 USDA H1
Note When starng a cold motor at below -20 °C, increased starng torques are to be expected due to the higher
viscosity of the roller bearing grease.
During project planning, allow a motor starng torque reserve of about 20%.
Commissioning at over +10 °C:
Operate the drive at max. 50% of the rated torque to avoid a reducon in service life.
Wide range
Ambient temperature -30 °C … +40 °C
Lubricant Synthec oil
CLP HC 220
Note When starng a cold motor at below -20 °C, increased starng torques are to be expected due to the higher
viscosity of the roller bearing grease.
During project planning, allow a motor starng torque reserve of about 30%.
At an ambient temperature generally over +30 °C:
The applicaon case must be checked by Lenze.
At a constant temperature between -30 °C and -25 °C, the service life is up to 20% lower than with the low-
temperature range.
Commissioning
Important notes