EasyManua.ls Logo

Lenze g500-S Series - Technical data; Notes regarding the given data

Lenze g500-S Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Incremental encoder
SinCos absolute value encoder with Hiperface©
Contact Designaon Meaning
B1 + UB Supply +
B2 GND Mass
B3 A Track A/+COS
B4 Track A inverse/-COS
B5 B Track B/+SIN
B6 Track B inverse/-SIN
B7 Z Zero track/+RS485
B8 Zero track inverse/-RS485
B10 Incremental encoder shield
Connecon of temperature monitoring
Contact Name Meaning
TB1 Thermal contact TCO
TB2
1TP1 PTC thermistor 150
1TP2
2TP1 PTC thermistor 130
2TP2
R1 + Thermal detectors PT1000 +
R2 - Thermal detectors PT1000 -
Blower connecon
1-phase
Contact Name Meaning
PE PE PE conductor
U1 L1 Mains connecon
U2 N
three-phase
Contact Name Meaning Note
PE PE PE conductor
U1 L1 Mains connecon Pay aenon to the direcon of rotaon!
Swap L1 and L2 if the direcon of rotaon is
incorrect.
V1 L2
W1 L3
Electrical installaon
Motor connecon
Connecon via terminal box