EasyManua.ls Logo

Lenze g500-S Series - Page 73

Lenze g500-S Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Motor M55BP
080M04 090M04 090L04 100M04 100L04 112M04
1 Rated eciency at full load, as well as at 75% and 50% of the rated load and rated voltage, determined for a frequency of 50 Hz and an
ambient reference temperature of 25 °C
Full load 82.5 84.1 85.3 86.7 87.7 88.6
75% 82.5 84.1 85.3 86.7 87.7 88.6
50% 82.6 84.4 85.1 87.9 88.3 89.8
2 Eciency level
IE3
3 Year of manufacture
Year and week of manufacture:
4Nameplates ^ 12
4 Name or trademark, ocial registraon number, and manufacturer's place of establishment
Lenze Drives GmbH
HR Lemgo B 6478
Breslauer Strasse 3
D-32699 Extertal
GERMANY
5 Model number of the product
M55BP
080M04 090M04 090L04 100M04 100L04 112M04
6 Number of motor poles
4 4 4 4 4 4
7 Rated output power in kW
0.75 1.1 1.5 2.2 3 4
8 Rated input frequency in Hz
50 50 50 50 50 50
9 Rated voltage in V
400 400 400 400 400 400
10 Rated speed in rpm
1455 1465 1465 1470 1470 1470
11 Relevant informaon for disassembly, recycling or disposal aer the nal decommissioning
12 Informaon regarding the range of operang condions for which the motor is specially designed
i) Altudes above sea level
0 … 1000 m
1000 … 4000 m: Reduce the power by 5 %/1000 m
ii) Minimum and maximum ambient air temperatures, also for motors with air cooling
-30 … +40 °C
iii) If appropriate, Cooling uid temperature at the inlet of the product
Not relevant, since motors are not liquid-cooled
iv) Maximum operang temperature
155 °C (temperature class F)
v) Potenally explosive atmospheres
Operaon in potenally explosive areas prohibited
Technical data
Motor data
Ecodesign direcve
73