EasyManua.ls Logo

Lenze i500 Series

Lenze i500 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
Troubleshoong
Operang Instrucons i510-Cabinet
8 Troubleshoong
8.1 Error message
If an error is pending, the keypad shows the following informaon.
1 = error text
2 = error type F = fault
T = trouble
W = warning
3 = error code (hexadecimal)
Faults (F) and trouble (T) are displayed connuously. The inverter is disabled.
Warnings (W) are displayed every 2 seconds for a short me. The inverter is probably disabled.
8.2 Reset error
Reset error via keypad
Errors can be reset using the key
if the cause of the error has been eliminated and no
blocking me is acve.
Press the key
to reset the error. The motor is stopped.
Press the key
to revoke the stop.
Reset error via terminal control
When terminal control is used, errors can be reset in 2 ways:
1. Via start signal P400.02 (default seng of digital input 1).
Cause of error has been eliminated and no blocking me is acve.
The signal at the digital input 1 (P400.02) must drop and then be applied again.
2. Via P400.04 (default seng of digital input 2).
Cause of error has been eliminated and no blocking me is acve.
The error is reset if a signal is applied to digital input 2 (P400.04).

Other manuals for Lenze i500 Series

Related product manuals