Inverter i550-C1.1/230-2 i550-C1.5/230-2 i550-C2.2/230-2 i550-C4.0/230-3
Rated power kW P
N
1.1 1.5 2.2 4
Rated power hp P
N
1.5 2 3 5
Mains voltage range 3/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-230/240 V
Rated mains current
without mains choke A I
r, AC
7.8 9.5 13.6 20.6
with mains choke A I
r, AC
5.6 6.8 9.8 15.7
Apparent output power kVA A
ON
2.2 2.6 3.6 6.4
Rated output current
2 kHz A I
OUT
6 7 9.6 16.5
4 kHz A I
OUT
6 7 9.6 16.5
8 kHz A I
OUT
6 7 9.6 16.5
16 kHz A I
OUT
4 4.7 6.4 11
Power loss
2 kHz W 36 41 54 113
4 kHz W 37 43 60 115
8 kHz W 42 50 70 130
16 kHz W 51 59 78 116
at inverter disablecontroller
inhibit
W 6 6 6 6
Overcurrent cycle 180 s
Max. output current A I
max, out
9 10.5 14.4 24.8
Overload me s t
ol
60 60 60 60
Recovery me s t
re
120 120 120 120
Max. output current during the
recovery me
A 4.5 5.3 7.2 12.4
Overcurrent cycle 15 s
Max. output current A I
max, out
12 14 19.2 33
Overload me s t
ol
3 3 3 3
Recovery me s t
re
12 12 12 12
Max. output current during the
recovery me
A 4.5 5.3 7.2 12.4
Cyclic mains switching 3 mes per minute
Brake chopper
Max. output current A I
max, 1
12 12 12 26
Min. brake resistance Ω R
min
33 33 33 15
Max. motor cable length shielded
without EMC category m 50 50 50 50
Category C1 (2 kHz, 4 kHz, 8
kHz)
m - - - -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m - - - -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m - - - -
Weight kg 1.35 1.35 1.35 2.1
Weight lb 3 3 3 4.6
Technical data
3-phase mains connecon 230/240 V
Rated data
101