Inverter i550-C1.1/230-1 i550-C1.1/230-2 i550-C1.5/230-1 i550-C1.5/230-2
Rated power kW P
N
1.1 1.1 1.5 1.5
Rated power hp P
N
1.5 1.5 2 2
Mains voltage range 1/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-230/240 V
Rated mains current
without mains choke A I
r, AC
14.3 14.3 16.7 16.7
with mains choke A I
r, AC
11.9 11.9 13.9 13.9
Apparent output power kVA A
ON
2.2 2.2 2.6 2.6
Rated output current
2 kHz A I
OUT
6 6 7 7
4 kHz A I
OUT
6 6 7 7
8 kHz A I
OUT
6 6 7 7
16 kHz A I
OUT
4 4 4.7 4.7
Power loss
2 kHz W 36 36 41 41
4 kHz W 37 37 43 43
8 kHz W 42 42 50 50
16 kHz W 51 51 59 59
at inverter disablecontroller
inhibit
W 6 6 6 6
Overcurrent cycle 180 s
Max. output current A I
max, out
9 9 10.5 10.5
Overload me s t
ol
60 60 60 60
Recovery me s t
re
120 120 120 120
Max. output current during the
recovery me
A 4.5 4.5 5.3 5.3
Overcurrent cycle 15 s
Max. output current A I
max, out
12 12 14 14
Overload me s t
ol
3 3 3 3
Recovery me s t
re
12 12 12 12
Max. output current during the
recovery me
A 4.5 4.5 5.3 5.3
Cyclic mains switching 3 mes per minute
Brake chopper
Max. output current A I
max, 1
12 12 12 12
Min. brake resistance Ω R
min
33 33 33 33
Max. motor cable length shielded
without EMC category m 50 50 50 50
Category C1 (2 kHz, 4 kHz, 8
kHz)
m 3 - 3 -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 - 20 -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 - 35 -
Weight kg 1.35 1.35 1.35 1.35
Weight lb 3 3 3 3
Technical data
1-phase mains connecon 230/240 V
Rated data
85