EasyManua.ls Logo

Lenze L-force 9400 Series

Lenze L-force 9400 Series
583 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Single-axis controllers
General data and operating conditions
4
44
EDS94SPP101 EN 7.1
EMC
Operation on public supply
systems
EN 61800-3
The controllers are designed for use in an industrial
environment. Operation on public networks requires
measures to be taken for limiting the expected emission of
radio interferences.
Noise emission, in cables
Design
”Single Drive”
EN 61800-3 see Tab. 4-2 EMC protection requirements
Design
”Multi Drive”
Depending on the filter at the central DC supply module.
Noise immunity (to EN 61800 -3)
Electrostatic discharge
(ESD)
EN 61000-4-2 8 kV with air discharge,
4 kV with contact discharge against housing
Radio frequency
Cable-guided EN 61000-4-6 150 kHz ... 80 MHz, 10 V 80 % AM (1 kHz)
Interference (housing) EN 61000-4-3 80 MHz ... 1000 MHz, 10 V/m 80 % AM (1 kHz)
Burst
Power terminals and
interfaces
EN 61000-4-4 2kV/5kHz
Signal interfaces EN 61000-4-4 1kV/5kHz
Control connections EN 61000-4-4 2kV/5kHz
Surge (surge voltage)
Power terminals EN 61000-4-5 1.2/50 μs,
1 kV phase/phase, 2 kV phase/PE
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Table of Contents

Other manuals for Lenze L-force 9400 Series

Related product manuals