Control connecons
Control connecons with M12 connectors
Via the digital inputs of the two M12 control connecons, it is possible to switch between
dierent speeds and direcons of rotaon. Up to 5 dierent speed sengs (e.g. creep speed
and normal speed in both direcons, as well as stop) can thus be selected. In addion, the
operang state is indicated via a digital output.
Control connecon X1 with M12 connector, A-coded, pins
Pin assignment
Con-
t
act
Name Meaning
1 n.c.
2 DI2 Digital input 2
3 GND-I Earth of digital inputs
4 DI1 Digital input 1
Control connecon X2 with M12 connector, A-coded, pins
Pin assignment
Con-
t
act
Name Meaning
1 24 V 24 V-supply (DO1 supply)
2 DI3 Digital input 3 (reference X1;3 = GND-I)
3 GND-O Earth of digital outputs
4 DO1 Digital output 1
Mounng/
installaon
Electrical installaon
Control connecons
64