Safety engineering
Acceptance
Periodic inspections
1
72
EDS94AYAF EN 1.0
Scope of test
A complete test comprises the following:
ƒ Documenting the plant including the safety functions:
Creating an overview screen of the plant
Describing the plant
Describing the safety equipment
Documenting the safety functions used
ƒ Checking the function of the safety functions used:
"Safe torque off" function, STO
"Safe stop 1" function, SS1
"Safe stop 2" function, SS2
"Safe operational stop" function, SOS
"Safe maximum speed" function, SMS
"Safely limited speed" function, SLS
"Safe stop emergency" function, SSE
"Safe direction" function, SDI
"Safely limited increment" function, SLI
"Safely limited absolute position" function, SLP
"Position−dependent safe speed", PDSS
"Safe cam" function, SCA
"Safe referencing" function, SREF
"Repair mode select", RMS
ƒ Preparing the test report:
Documenting the functional test
Checking the parameters
Signing the test report
ƒ Preparing the appendix with test records:
Protocols from the plant
External recording
1.9.2 Periodic inspections
The correct sequence of the safety−oriented functions must be checked in periodic
inspections. The risk analysis or applicable regulations determine the time distances
between the tests. The inspection interval should not exceed one year.