EasyManua.ls Logo

Lenze SM302 - Safety Instructions

Lenze SM302
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety engineering
Basics
Safety instructions
1
9
EDS94AYAF EN 1.0
1.1.6 Safety instructions
Application as directed
The safety modules SMx (E94AYAx) may only be used together with Lenze drive controllers
of the L−force | 9400 (E94A... / E94B...) series.
Any other use shall be deemed inappropriate!
Installation/commissioning
Danger!
Danger to life through improper installation
Improper installation of safety engineering systems can cause an uncontrolled
starting action of the drives.
Possible consequences:
ƒ Death or severe injuries
Protective measures:
ƒ Safety engineering systems may only be installed and commissioned by
qualified and skilled personnel.
ƒ All control components (switches, relays, PLC, ...) and the control
cabinetmust comply with the requirements of EN ISO 13849−1 and EN ISO
138492. Thisincludes i.a.:
Switches, relays with at least IP54 enclosure.
Control cabinet with at least IP54 enclosure.
Please refer to EN ISO 13849−1 and EN ISO 138492 for all further
requirements.
ƒ It is essential to use insulated wire end ferrules for wiring.
ƒ All safety relevant cables outside the control cabinet must be protected, e.g.
by means of a cable duct:
Ensure that no short circuits can occur.
For further measures see EN ISO 138492.
ƒ If an external force acts upon the drive axes, additional brakes are required.
Please observe that hanging loads are subject to the force of gravity!