Final c
onguraon
Check
Connecon dimensions Output sha
Output ang
e/foot
Mounng posion Geared motor
Terminal box
Driven sha/output ange
Product extensions Torque support
Sha c
over
Connectors
Brake
More in
formaon about the nal conguraon:
4The modular system ^ 12
4Product extensions ^ 78
Parameters that can be preset by Lenze
The parameters marked with "order-dependent" in the standard seng c
an be
preset order-related by Lenze.
Standard sengs
Parameter Value Comment
Designaon Delivery Seng r
ange
Parameter set name --- [Text] File name of the parameter set without le
extension *.lsm
Output speed 1 depending on the order [-2600/i ... -500/i] rpm
[0]
rpm
[500/i ... 2600/i] rpm
CCW rotaon: < 0 rpm
STOP: 0 rpm
CW rotaon: > 0 rpm
Lenze Smart motor with gearbox: The rao i is
taken into account in the calculaon of the output
speed.
Output speed 2
Output speed 3
Output speed 4
Output speed 5
Acceleraon me [0.0 ... 20.0] s
Acceleraon me t
1
of the ramp generator from
0 rpm to n
max
[2600/i] rpm
Deceleraon me Deceleraon me t
2
of the ramp generator from
n
max
[2600/i] rpm to 0 rpm
Energy-saving funcon [O] Opmized f
or:
•
High dynamic performance
•
Maximum starng torque and torque
•
High speed accuracy
[On] Reduced energy ab
sorpon in paral load
operaonal range.
Approx. 50 % of the maximum starng torque are
available.
Informaon on pr
oject planning
Final conguraon
25