LD5208 USER MANUAL, REV. 0: NOVEMBER 2005
26
12. TROUBLE SHOOTING
In case of an unexpected event, caused by software or hardware reasons, the operator is prompted
with the message E r r x x , where xx is the Error code. Program is halted.
Press ) momentarily to acknowledge the error and proceed as indicated in the error operator
response. Errors may occur during setup, programming, power-up and during operation.
In all other cases of malfunction the user should contact the supplier, as the unit may probably
need service from an experienced technician
LIST OF ERROR CODES
DISPLAY POSSIBLE CAUSE ACTION TO BE TAKEN
Err 01
SYSTEM ROM : Faulty EPROM.
Contact manufacturer.
Err 02
DATA RAM : Faulty CMOS RAM.
Contact manufacturer.
Err 04
CALIBRATION DATA : Faulty
EEPROM.
Contact manufacturer.
Err 05
SCALE or A/D CONVERTER.
Check scale, cable, connectors,
contact manufacturer.
Err 06
LOW INPUT VOLTAGE .
Check power supplied to the
instrument.
Err 15
System has been initialised due to
power failure or soft reset.
Zero scale.
Err 20
PRINTER IS NOT ON-LINE. Either not
connected or out of paper or failed.
Check printer cables. Press ( to retry
Or ) to abort.
Err 26
No paper for EPSON TM295 printer.
Supply with paper.
Err 50
Small sample count.
Retry.
Err 51
Small sample weight.
Retry.
Err 67
Corrupted totaliser.
Clear totalising memory.
Err 69
TOTALISER OVERFLOW.
Because totalisers have not been
cleared for long time.
Print / clear totalisers. Overflow is not
critical. But remember that 1 total
capacity must be added to the
indication, each time an overflow
occurs.
.
..
. To exit from error display press ) .