EasyManua.ls Logo

Leuze electronic BCL 8 Series - MA 8.1 - BCL - Connecting the BCL 8 to the MA 8.1; Figure 5.5: MA 8.1 - Pin Assignment BCL

Leuze electronic BCL 8 Series
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories / order codes
22 BCL 8 Leuze electronic
5.2.4 MA 8.1 - BCL - connecting the BCL 8 to the MA 8.1
Figure 5.5: MA 8.1 - Pin assignment BCL
Attention!
Protection class IP 67 is achieved only if the connectors and caps are screwed into place!
The BCL 8 is connected to the MA 8.1 via the connection cable KB 008-1000/2000/3000
(AA/AR). The voltage supply is connected via the PWR IN HOST/RS 232 socket.
Attention!
It is absolutely necessary to connect functional earth, since all electrical interference (EM
pick-up) is discharged via the functional earth connection.
BPS (5-pin socket, A-coded)
Pin Name Remark
1VIN
Supply voltage for BCL 8
+4.9 +5.4VDC
2 TXD Transmission line RS 232
3 GND Supply voltage 0VDC
4 RXD Receiving line RS 232
5
SWIN/
SWOUT
Programmable switching input/output of the
BCL 8
Thread FE Functional earth (housing)
1
23
4
5
RXD VIN
GND
SWIN/SWOUT
TXD
BCL 8
M12 socket
(A-coded)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com