Basic configuration
Leuze electronic BPS 300i 54
Sw. inputs/outputs
IO1 HIGH
Function: Position value invalid
Switching output - level controlled
If a valid position value cannot be
ascertained, the output is set
IO2 HIGH
Function: Preset teach
Switching input - edge-triggered
Transition 0 1: Read in preset value
Parameters Factory settings Description