User Manual for BPS-2000
www.levitronix.com
PL-4021-00, Rev03, DCO# 15-235
Figure 22: Temperature curves of motor LPM-2000.2 with Air Cooling Module ACM-4.2
(Temperature is measured inside of the motor, temperature of housing and sensor electronics is significantly below this temperature)
77
97
117
137
157
177
197
0 5 10 15 20 25 30 35
25
35
45
55
65
75
85
95
0 20 40 60 80 100 120 140
[°F]
[gpm]
[
0
C]
[lpm]
Ambient Temp = 25 C
Liquid Temp. = 40 C
Specific gravity = 1 g/cm3
Viscosity = 0.7 cP
Air cooling with ACM-4.2
1 bar, ~25 C air
Absolute Temperature Limit
Recommended Operational Limit
77
97
117
137
157
177
197
0 2 4 6 8 10 12 14 16 18 20 22
25
35
45
55
65
75
85
95
0 10 20 30 40 50 60 70 80
[°F]
[gpm]
[
0
C]
[lpm]
Ambient Temp = 25 C
Liquid Temp. = 40 C
Specific gravity = 1 g/cm3
Viscosity = 0.7 cP
Air cooling with ACM-4.2
1 bar, ~25 C air
Absolute Temperature Limit
Recommended Operational Limit
High-Flow System
Pump Head LPP-2000.6
High-Pressure System
Pump Head LPP-2000.7