EVENT LIST
Selecting the Event List option accesses the
Event List screen shown in Figure 18 (above).
This screen can be used to modify program
change and mute event times. Parameter
change events are not displayed on this
screen.
Editing Rules & Restrictions
The Event List screen can be used to delete
unwanted program and mute events, as well
as to make small adjustments to program and
mute event positions to match events on-
screen or in music. It is also possible to make
large adjustments. However, it is important to
understand the consequences.
For program event editing:
• Each automation session must have at
least one program event for each machine.
This event begins at time 00:00:00:00
(relative to Session Offset) and defines the
default state of the machine.
• Any program event can be deleted or
moved, except the last remaining program
event.
• If the first program event on the list is
deleted, the earliest remaining event will
move to time 00:00:00:00.
• Program events can only be moved to
the spaces between the preceding and
following events. Program events cannot
be moved ahead of the preceding
program event, or behind the following
program event.
• When a program event is deleted, all
parameters associated with that program
are also deleted.
Automation Package Addendum
Lexicon
20
Figure 18: Event List Screen
To access the Event List screen:
1. Follow the instructions on page 10 to
access the Automation Menu.
2. Select the Event List option.
Modifying Event Times
To modify an event time:
1. Follow the instructions above to access the
Event List screen.
2. Use the up and down arrow keys on the
LARC2 to select the event to be modified.
3. Use the left and right arrow keys on the
LARC2 to select the TIME field to be
modified – from left to right: hours,
minutes, seconds, or frames.
4. Use the + and – keys on the LARC2 to
increase or decrease the selected time
field, or enter the time directly using the
numeric keypad on the LARC2.