EasyManuals Logo

Lexicon LXP-5 - REV 1 User Manual

Lexicon LXP-5 - REV 1
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
3-13
MIDI Operation
Disabling a Global Patch
Global patches can be disabled from the front panel of the LXP-5. To do this,
simply turn FUNCTION to EDIT A, turn SELECT to position MAX, and set
ADJUST according to the following table:
ADJUST GLOBAL PATCH
Knob Position EDIT
MIN - 6 Disables all global patches
7 - 11 Re-enables a global patch after
moving associated MIDI controller
12 - MAX Re-enables all global patches immediately
ADJUST NOTE SCALE
Knob Position DURATION VALUE
MIN Half Note 0
2 Dotted Quarter 1
3 Half Triplet 2
4 Quarter Note 3
5 Dotted Eighth 4
6 Quarter Triplet 5
7 Eighth Note 6
8 Dotted Sixteenth 7
9 Eighth Triplet 8
10 Sixteenth 9
11 Sixteenth Triplet 10
12 Thirty-second 11
This feature can only disable and re-enable all existing global patches. It
cannot be used to create new global patches.
Note: The global patch sources for parameters 0-22 are intitialized at
the factory to correspond to MIDI controllers 8-30. The LXP-5 is
shipped with global patches
disabled
.