4-4
LXP-5 Owner's Manual
Parameter Adjust
Byte Value Description
0 F0 (hex) System Exclusive
1 06 Lexicon ID
2 05 LXP-5 ID
3 0010 nnnn(bin) n = MIDI Channel 0-15
4 0ppp pppp p = parameter number 0 - 127
5 0vvv vvvv 7-bit data
6 F7 (hex) End of SysEx message
All User Data
Byte Value Description
0 F0 (hex) System Exclusive
1 06 Lexicon ID
2 05 LXP-5 ID
3 0100 nnnn(bin) n = MIDI Channel 0-15
4 39 (hi) (hex) data byte count
5 00 (lo) (7296 = 0x1c80 = 0x3900 in 7-bit)
6 0vvv vvvv(bin) 7-bit data
.
7301 0vvv vvvv
7302 0sss ssss sumcheck of data bytes
7303 F7 (hex) End of SysEx message
Data Dump Contents
Single Program and All User Data Dump
The Single Program and All User Data dump share the same format. The
Single Program dump sends all of the stored parameters for the selected
setup; the All User Data dump sends all 128 copies of the stored programs.
Remember, all LXP-5 parameter data is 7-bits wide. The format is shown on
the following page.