6.1.2 Heating Mode
+2°C.
+4°C.
Comp. OFF
Comp. ON Comp. OFF Comp. ON Comp. OFF
INV. Comp.
Frequency
Constant
Comp.
Low
High LowHigh Comp. OFF
Thermo
ON
Thermo
OFF
Setting
Temp.
Operating frequency of compressor depend on the load condition, The difference between the room temp. and set
temp., frequency restrictions.
If compressor operates at some frequency, the operating frequency of compressor cannot be changed within 30 sec-
onds.
Condition of compressor turned off
- When intake air temperature reaches +4°C above the setting temperature.
Condition of compressor turned on
- When intake air temperature reaches +2°C above the setting temperature.
* Condition of indoor fan turned off
- While in compressor on : indoor pipe temp. < 20°C (Option)
- While in compressor off : indoor pipe temp. < 30°C (Option)
While in defrost control, between the indoor and outdoor fans are turned off.
Compressor 3 minutes delay
- After compressor off, the compressor can restart minimum 3 minutes later.
NOTE: Some Models are different by temperature of thermo ON/OFF.

Table of Contents

Other manuals for LG Single "A"

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG Single "A" and is the answer not in the manual?

LG Single "A" Specifications

General IconGeneral
BrandLG
ModelSingle "A"
CategoryAir Conditioner
LanguageEnglish

Related product manuals