- 38 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 2 Functions & Controls
Installer Setting -Thermistor
j Therefore system will use value that sensed from indoor unit or remote controller
Temperature sensor location Function
01 Remote controller Operation in remote controller temperature sensor
02 Indoor unit Operation in indoor unit temperature sensor
03 2-Thermistor(2TH)
Operation in lower temperature after comparing the temperature between the indoor unit
And remote controller
<Thermistor Table>
Function Code Thermistor setting
Press button for 4 seconds
to enter the installer setting
mode until timer segment
display “01:01”.
1
Set Thermistor mode by pressing
button. (01: Remote Controller,
02: Indoor, 03: 2TH)
3
Press button to save or release.
4
Press button to exit or
system will automatically exit
after 25 seconds without any
input.
5
Repeat pressing button to select
Function code 04.
Ex) Setting Thermistor as '2TH'.
2