8.4 Main PCB Appearance
(1) [DIP SW2] for [SETTING No. OF IDU] OR [LONG
PIPE].
1 TO 3 PIN SWITCHES RECOGNIZE IDU NORMAL-
LY BEING UP AND DOWN ONE BY ONE.
(2) [SW01B] for [AUTO-ADDRESSING]
(3) [LED01G/LED02G] for SIGNALS
Table 1. signals
8.5 Auto addressing guide
Addressing work assigns address to each indoor unit.
When firstly installing product of roplacing the indoor unit
PCB.
It needs Auto Addressing for Synchro operation
❈ Work procedure
1) DIP SW2 correctly.( )
2) Turn on main power.
3) Press the SW01B for about 3 seconds within 3minutes
After main power on.( )
4) After step 3), the LED01H(green LED) rapidly flick-
ers.When Addressing work is done, green LED is off,
else LED stops flickering and lights continuously.
5) If you fail to perform the Addressing work, repeat step
2),3).