Installation check listConguration
System Design ApplicationsIntroduction
Installing remote temperature sensor
Remote temperature sensor can be installed any place a user wants to detect the temperature
Distance between the indoor unit and the remote air temperature sensor should be less than 15 m
due to length of the connection cable of remote air temperature sensor.
Connect the wire between CN_Room in PCB and remote room sensor
CN_ROOM
[Remote room sensor]
Press up’ for 3 sec
Installer setting
CN_ROOM
[Remote room sensor]
Press up’ for 3 sec
Enter installer setup mode, then Set
Remote sensor active “Use” Set Temp.
sensor selection “Air” .
System diagram
DHW tank
DHW
Temp. sensor
IDU
Purpose: Conguration for DHW exclusive operation. System is set up by connecting piping to heat
exchanger installed in DHW tank.
Necessary conguration and feature
Dip s/w Separate setup is required Dip s/w No. 3: On
Remote controller
Use the default one attached to indoor unit
No installation required
Leaving water temperature
DHW temperature is set by remote
controller
Single temperature
control Control of DHW temperature sensor
DHW temperature can be set after
initiating heating operation
DHW temperature sensor
Installation
Temperature sensor that came with DHW
tank needs to be installed.
Booster heater If not applied, and tank kit is not used
Dip s/w Setting
OFF
ON
1 23 45678
016 017
_