COMBO
WM3677 COMBO Page 46 of 68 TRAINING MANUAL
TUB REMOVAL AND REPAIR, continued.
1. Remove the back cover. (Six
screws.) Remember to drain the
water if you haven’t already
done it.
2. Remove the large bolt securing
the rotor. This is much easier if
there is an assistant available to
hold the drum still on the inside
while loosening the bolt.
Extreme torque is not required
when replacing the bolt; instead
use a drop of Loctite
®
.
Use extreme caution! This part
holds the motor’s permanent
magnets.
3. Disconnect the electrical
connections and grounding
screw.
4. Remove the 6 bolts that hold the
windings in place.
5. Disconnect the small hose that
attaches to the water level
sensor.
6. Disconnect the dryer duct hose.
7. Disconnect the drain hose on
the back of the pump.
8. Disconnect the recirculating
hose at the top of the door
gasket.
9. Disconnect the air vent hose.
Be especially careful of the ball
check valve. It must be replaced
correctly to function properly.
10. Disconnect the vacuum break.