Specifications:
Page 10 of 28
• Nominal input voltage (mains voltage): 100 V AC - 240 V AC
+10/-15%, Universal input voltage
• Nominal input frequency: 50 Hz / 60 Hz
• Typical standby power consumption: Approx. 0.1 W
• Housing colour: Dark Olivish Grey
• Protection class: IP66
Usage:
• Compatibility: LA12 IC
TM
, LA14 IC
TM
, LA23 IC
TM
, LA25 IC
TM
and LA35 IC
TM
, only 24 V DC
• Duty Cycle: 10%, 2 minutes continuous use followed by 18 minutes not in use.*
• Operating temperature: -20°C to 40°C
• Storage temperature: -40°C to 70°C
• Relative humidity: 20% to 90% @ 30°C – not condensing
• Atmospheric pressure: 700 to 1060 hPa
• Altitude: Max. 2000 metres above sea level
• To extend/retract the actuator: A voltage greater than 21 V DC must be applied to red/black wire.
• To stop extending/retracting
the actuator: A voltage less than 9 V DC must be applied to red/black wire
(normally 0 V DC)
• Approvals: The SMPS-T160 is approved according to the following standards:
• 2004/108/EC, EMC Directive
• 2006/95/EC, Low Voltage Directive
• EMC Standards:
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2:1997+A1:2001+A2:2008
EN 61000-3-2:2006+A1:2009+A2:2009
EN 61000-3-3:2013
• Safety Standards:
EN 61558-1:2005+A1:2009
EN 61558-2-16:2009+A1:2013
* Please be aware that the SMPS-T160 has a lower duty cycle than the actuator. This must be respected!