HB22RF2000 in general:
Massage will turn off automatically 10 min after the last adjustment of the settings. Default by TD1, TD3 and
CBH Advanced. TD3/CBH Advanced can be configured.
Adjusting the bed will turn off the massage, but massage will automatically start up again afterwards.
When turning on a single massage motor it will start up with the same intensity as it was last time it was running as a
single motor.
When turning on a massage program it will start up with the same settings (program, motor change speed, intensity, wave/
pulse, frequency) as it was last time.
When in massage mode, turning on a massage function can also be done by keeping the up button pressed. Then it will turn
on, and after a short delay adjust the intensity up.
In case of any error: current limitation, high temperature or short circuit, the massage system will stop both motors, even if
only one motor is affected.