IS09 ECN2087
10
User Instructions
• Retain these instructions for future reference.
• Ensure that the spillage tray is in the correct position before operating the appliance.
• Care should be taken to avoid injury whilst operating the appliance at the water temperature is
maintained at approximately 98
o
C.
• Only qualified personnel should attempt any routine or necessary maintenance work on the
appliance.
Operating the Appliance
• Place a cup or suitable hot water container, central to the tap, upon the spillage tray.
• To draw off hot water, pull the faucet handle towards the user. Hot water will be dispensed at
a steady flow until the water capacity is reduced to the level of the spigot. Upon releasing the
faucet handle, the handle will return to the closed position.
• For larger containers the faucet handle may be pulled to the horizontal position thereby
locking the faucet open. The faucet handle will then have to be manually returned to the
closed position. Warning. Whilst the faucet handle is in the locked open position the
appliance must not be left unattended.
• As hot water is drawn off the appliance will automatically begin the fill cycle. The filling
cycle will continue until the appliance goes into standby mode. The length of the fill time to
full capacity depends upon the volume of hot water drawn off.
• Do not remove the lids from the appliance whilst in full operation as these parts become hot.
Cleaning
To clean the appliance use only a soft damp cloth and mild detergent. Do not us abrasives on the
mirror-finished surfaces as damage may result. Care should be taken when cleaning outer
surfaces whilst the appliance is in full operation as certain areas become hot during normal
operation.
It will be necessary from time to time during normal operation to inspect the spillage tray for
water. Empty the spillage tray as and when necessary.
Warning. The appliance is not protected against the ingress of water. The appliance must not be
submerged for cleaning purposes. Do not use water jet spray cleaning equipment on the
appliance. The appliance is splash protected and has the code IP24B.
Scale
The formation of scale within a hot water system is common and if left unchecked may cause
problems to the functioning of the appliance. In hard water areas scale formation builds up
quicker than in softer water areas therefore checks on scale formation need to be more frequent. It
is advisable, in order to prevent injury, the appliance be isolated and allowed to cool before
inspecting for scale deposits within the tank.
Warning. Under no circumstances should this appliance be connected to the outlet of a water
softener.
Please note that the manufactures guarantee will be void if faults arise which are due to excessive
build up of scale.
To help prevent scale build up a filter system can be installed with the appliance. The filter is
available as an optional extra upon request.