IS09 ECN2087
20
Neon
• Remove the outer lid.
• Remove the retaining screws from the back panel and slide the back panel vertically upward.
• Remove the retaining screws from the access panel.
• Loosen the tank-retaining bracket and ease that tank backward to gain access to the neon
housing. Note: Remove any additional parts as necessary in order to move the tank.
• Remove the wires from the neon terminals.
• Depress the neon housing and slide the housing free from the lens. Note: The lens will be free
to be extracted from the neon bezel.
• Fit the new neon housing and assemble in reverse order.
• Electrically test the appliance.
Faucet
• Evacuate the tank to the level of the faucet. Partially drain the tank as described in the de-
scaling routine.
• Loosen the faucet-retaining nut and remove the faucet. Note: To remove the faucet-retaining
nut, remove the circlip.
• Fit the new faucet and assemble in reverse order.
Tank
• Drain the tank as described earlier in the de-scaling routine.
• Remove the faucet.
• Remove the outer lid.
• Remove the retaining screws from the back panel and slide the back panel vertically upward.
• Remove the retaining screws from the access panel.
• Free the contactor/thermostat from the mounting bracket and remove the tank-retaining
bracket.
• Remove the middle and inner lids.
• Remove the drain hose from the tank connector.
• Remove the overflow hose form the tank vent pipe.
• Loosen the solenoid retaining screws.
• Remove the wires from the solenoid terminals, noting the connections.
• Remove the wires from the level sensors.
• Withdraw the tank.
• Remove the tank connector, level sensors and fit to the new tank.
• Fit the new tank and assemble in reverse order.
• Electrically test the appliance.
Protective Device
•
••
• Remove the back panel.
•
••
• Disconnect the wires from the protective device.
•
••
• Loosen the element retaining nuts.
•
••
• Remove the heat sink and protective device.
•
••
• Fit the new device and assemble in reverse order.
•
••
• Electrically test the appliance.