Technical Specifications
Dimensions
Model Height Width Depth
EB3 600mm 275mm 315mm
EB4 600mm 345mm 315mm
EB6 600mm 440mm 315mm
EB6/T 600mm 440mm 315mm
Weight
Model Dry Working
EB3 13.5kg 30.5kg
EB4 15kg 34.5kg
EB6 18.5kg 46kg
EB6/T 18.5kg 46kg
Capacities
Model Working Total
EB3 10 litres 16 litres
EB4 13litres 20.5 litres
EB6 18 litres 27.5 litres
EB6/T 18 litres 27.5 litres
Heat Up Time
Model From empty to lower
level sensor
From lower level sensor
to upper level sensor
EB3 12 minutes 27 minutes
EB4 9 minutes 32 minutes
EB6 9 minutes 35minutes
EB6/T 9 minutes 35 minutes
Rates
Model Faucet Rapid draw
off
Recovery Output
EB3 7.5 lmin
-1
10 litres 0.4 lmin
-1
22 lhour
-1
EB4 7.5 lmin
-1
13 litres
0.42 lmin
-1
24 lhour
-1
EB6 7.5 lmin
-1
18 litres 0.54 lmin
-1
31 lhour
-1
EB6/T 15 lmin
-1
18 litres 0.54 lmin
-1
31 lhour
-1
Note. Assuming both faucets are used simultaneously on the EB6/T
Drain Down
Model Full to Faucet Faucet to Empty
EB3 1.4 minutes 2 minutes
EB4 1.8 minutes 2.75minutes
EB6 2.4 minutes 3.5 minutes
EB6/T 1.2 minutes 3.5 minutes
Note. Assuming both faucets are used simultaneously on the EB6/T
Electrical
Model Volts Amps Watts
EB3
230 240 13.04 12.5
3000
EB4
230 240 19.56 18.75
4500
EB6
230 240 26.08 25
6000
EB6/T
230 240 26.08 25
6000