___________________________________________________________________________________________________________________________________________________________________________________________
___________________________________________________________________________________________________________________
Form 403760 Page Number - 19
TROUBLESHOOTING
Symptom Possible Cause Remedy
Battery Icon is displayed Batteries are low Replace batteries
Display Blank Meter asleep Push reset button
Batteries dead Replace batteries / Push reset
Button
Program error Remove and reinsert battery pack/
Push reset button
Loose battery connection Remove battery pack and check
battery connection / Push reset button
Meter does not latch for Meter not in AUTO mode Press AUTO button and program
batching batch size
Meter not reset after prior Press RESET button
batch
Low batteries Check for battery icon / replace
batteries / push RESET button
Slow or no fluid flow Filter is clogged Clean or replace the filter in the
swivel nut
Pump pressure is low Turn up the pump pressure
Foreign material is Contact your local distributor for
jamming meter repair
Meter inaccurate Scale factor not correct for Enter program mode, check and
fluid reset program factor
Relieve the pressure prior to
checking or repairing the meter.
Make sure all valves, controls and
pumps are operating correctly.
To order call 1-800-548-1191 or visit www.partdeal.com - info@partdeal.com