27
WWW.LIONPROTECTS.COM
11. ATTACK
™
TRANSPORTATION
The ATTACK Training System is ready for transport after the steps of the “Shut Down
Operation” have been performed.
When transporting ATTACK, the following procedures should be followed:
1. The laser extinguisher should be turned off with the hose rmly positioned within
the hose clip. Store and transport the laser driven extinguisher in a protective
box or case. Be careful not to knock or drop the laser extinguisher during
transportation. Be sure to charge your laser extinguishers every 3–6 months during
long storage periods.
2. SmartExtinguishers MUST be de-pressurized prior to transportation. During
transportation, LION recommends removing the headstock of the SmartExtinguishers
to ensure that they are de-pressurized.
3. SmartExtinguishers should be drained of water and allowed to dry before
transporting.
4. ATTACK and all its parts should be completely clean and dry prior to transportation
and/or storage.
5. During long-term storage, leave all cases open to allow unit to dry out. Closing wet
parts in the storage cases will cause corrosion and possible mold growth.
6. Transport cases for the ATTACK Panel and weighted base are available from LION.
7. Do not ship the Smoke Generator in the watertight case unless it is in an additional
box that provides adequate cushion to prevent damage.