Rev: 06.29.18
Page 12
CCD-0001535
Manual Override - Jacks
In the event that the jacks will not extend or retract, the valves can be manually overridden by using a ⁄”
hex wrench to turn the manual override clockwise on the valve (See Fig. 7). The leveling jacks can then be
extended or retracted. Remember to turn the manual override completely counterclockwise (See Fig. 8)
until it will no longer turn to close the valve after the jacks have been completely extended or retracted. Do
not over-tighten override set screws, as this can damage the valves.
Manual Override - Power System
The Lippert LCI Level-Up Motorhome Leveling System can be run with auxiliary power devices like cordless
or power drills. In the event of electrical or system failure, this manual method of extending and retracting
the jacks can be used. A standard handheld drill is all that is required. See the instructions below.
Clockwise for manual override
Counterclockwise for normal operation
1. Remove plastic cap (Fig. 9A).
2. Disconnect or shield power cables on the motor.
3. Using a ½” socket and auxiliary drive device, i.e. cordless or power drill, insert ½” socket onto coupler
found under plastic cap (Fig. 10A).
4. Run drill in reverse or counterclockwise to retract jacks.
Fig. 7 Fig. 8
Fig. 9 Fig. 10
AA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components LCI Level-Up and is the answer not in the manual?

Lippert Components LCI Level-Up Specifications

General IconGeneral
BrandLippert Components
ModelLCI Level-Up
CategoryControl Systems
LanguageEnglish

Related product manuals