Page #9 background image
Rev: 06.29.18
Page 9
CCD-0001535
Low Voltage Signal
1. The vehicle requires 12.7V DC to operate in the AUTO mode. If the voltage is too low, the screen will
display LOW VOLTAGE. If voltage drops below 12.7V DC, the system will only operate in the MANUAL
MODE and continue to display LOW VOLTAGE.
2. Minimum Voltage - If voltage drops below 9.5V DC during AUTO or MANUAL operation LOW VOLTAGE
will appear in the screen and the system will cease operating.
Error Mode
Excess Angle
1. The control will not operate at extreme slopes, i.e. 3.5 degrees fore and aft and 3.5 degrees side to
side.
2. If the coach indicates “EXCESS ANGLE” or “JACKS STROKED OUT“ during an auto level cycle, move the
coach to a more level spot.
Error Mode
NOTES:
If an error occurs before or during operation, the error will be displayed in the LCD and an alarm will
sound. To reset all error or service displays, push RETRACT and ENTER at the same time.
All normal functions will be disabled when the system is in Error Mode.
Auto Level can only commence if running voltage is 12.7V DC or above.
Auto Level operation will halt if running voltage drops to 9.5V DC.
Manual Level operation can be performed at all running voltages above 9.5V DC.
Error Text Description
Excess Angle Excess slope for auto leveling
Feature Disabled Control not zeroed
External Sensor Remote sensor short or disconnected
Out of Stroke
Check campsite for even, level ground and turn engine
on - Check battery voltage under load.
Low Voltage Turn engine on - Check battery voltage under load.
Function Aborted Panic stop
Jack Timeout Auto mode/Retract timeout
Auto Level Fail Unable to level
Not Configured Control not zeroed
Zero Not Set Control not zeroed
Battery Voltage Turn engine on - Check battery voltage under load
Apply Park Brake to Auto Level Set parking brake
Unit has retracted for longer
than 50 seconds
Retract timeout, return leveling jacks for service.
Latched retract mode
Unable to Finish Leveling Move coach to a more level site
Check Wiring
Touch Pad is powered, but not communicating with
the controller. Check pin 1 and 2 of touch pad harness.
Caution, Excess Run Time Pump run too long in manual mode
Latched Retract / Service
Check for leaking jack hose or fitting, reset by pressing
retract and enter at the same time.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components LCI Level-Up and is the answer not in the manual?

Lippert Components LCI Level-Up Specifications

General IconGeneral
BrandLippert Components
ModelLCI Level-Up
CategoryControl Systems
LanguageEnglish

Related product manuals