Disassembling the Meter
This topic explains how to disassemble the Meter, including how to:
·
Remove non-corroded rotor gears
·
Remove corroded rotor gears
·
Remove the bearing plates and rotors
Follow this procedure to begin disassembling the Meter:
1. Remove the counter bracket screws with a box wrench or socket driver. The counter
bracket can be removed with or without removing the adjuster assembly.
2. Turn the meter on either the inlet or outlet side. Let it stand to allow the product to drain
from the meter chamber.
3. Locate the drain plugs on the front and rear covers. Remove the drain plugs using an
allen wrench. Let the meter stand to allow product to drain from the front and rear
covers.

Other manuals for Liquid Controls M Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Liquid Controls M Series and is the answer not in the manual?

Liquid Controls M Series Specifications

General IconGeneral
Temperature Range-40°F to +160°F (-40°C to +71°C) standard, extended ranges available
Materialsstainless steel
TypePositive displacement flow meter
Fluid Compatibilityfuels, oils, and chemicals
Sizes6"
Output OptionsPulse

Related product manuals