overvoltage occurs at the beginning of Speed
Search and DC Braking.
Uv
(Undervoltage)
Detection Delay
Time
Sets the Delay time of undervoltage
detection.
Default: 15ms
Range: 0 to 1000ms
Uv
(Undervoltage )
Detection Level
Sets the voltage level of undervoltage
detection or KEB function activation.
Default: Determined
by d1-00, o2-03
Min.: 150V
Max.: 210V <3>
Sets the time to decelerate during KEB
function.
Default: 0.0 s
Min.: 0.0 s
Max.: 6000.0 s
Acceleration
Time after KEB
Sets the time to reaccelerate from the speed
when KEB function was deactivated to the set
frequency command (operation frequency
before power loss).
When set to 0.0 s, the drive will accelerate to
the previously active frequency according to
the active acceleration time set by any of C1-
00, C1-02, C1-04 or C1-06.
Default: 0.3 s
Min.: 0.0 s
Max.: 6000.0 s
Sets the minimum duration of KEB operation
after activation.
KEB function will operate according to this
detection time even if power recovers within
this duration.
Default: 50 ms
Min.: 0 ms
Max.: 2000 ms
Voltage Target
During KEB
Sets the target value for the main circuit DC
voltage or to deactivate KEB.
Default: <2>
Min.: 150V
Max.: 400V <3>
0 : KEB Operation Method 1
1 : KEB Operation Method 2
2 : KEB Operation Method 3
Default: 0
Range: 0, 1, 2
Automatic
voltage
regulation (AVR)
0 : AVR is disabled
1 : AVR is enabled
Stall Prevention
during
Acceleration
0 ∶ Disabled
1 ∶ Enabled the value set in P3-01.
Acceleration stops when the output current
exceeds the value set in P3-01. Acceleration