(Note) When the set value is greater than the
target value.
Stop level is the target pressure and start
level is 0
(Switch mode)
Detection time
setting
Set the percentage of time and calculate the
detection time to determine whether to enter
the switch mode.
Set 0: Switch mode function is off
Default: 40
Min.: 0
Max.: 100
Unit: 1%
(Water detection)
Elevate the level
Raise a specified pressure level to detect
whether water is currently used
Default: 5
Min.: 0
Max.: 100
Unit: 1%
(Water
Detection)
Pressure Limit
Time "Limit"
Set the limit time of F1-03 (Pressure Lift Level)
to detect whether water is currently used.
Set 0: the function is off
Default: 0.0
Min.: 0.0
Max.: 25.0
Unit: 0.1s
(Water
detection)
Pressure
increase interval
Set the time interval of F1-03 (pressure
increase level) to detect whether water is
currently used.
Setting 0: Water detection function is turned
off
Default: 35
Min.: 0
Max.: 250
Unit: 1s
(Water
detection)
Inverter standby
(sleep) level
When the inverter running frequency is lower
than the set value, it will automatically
decelerate to 0Hz and enter the standby
(sleep) state.
Default: 5
Min.: 0
Max.: 60
Unit: 1Hz
PID control
recovery level
setting
When the inverter is in the standby (sleep)
state, when the pressure drops to the recovery
level, the inverter starts and enters the PID
control mode.
Recovery level: set pressure (SV)-F1-07 set
value
(Note) When the set value is greater than the
target pressure, the recovery level is 0Hz
Default: 15
Min.: 0
Max.: 100
Unit: 1%
PID steady state
allowable error
Provide error range to determine whether
PID control has reached stability
Default: 5
Min.: 0
Max.: 100
Unit: 1%
(Water shortage
detection)
Pressure level
Set the pressure level to detect if the pump is
in a state of water shortage. Set 0 to turn off.
When F1-19 = 0,
Default: 10.0
Min.: 0.0
Max.: 100.0
Unit