86
Parameter
Name
Description
Setting Range
5
Feedback Low /High Fault (detection
disabled when PID is disabled)
6 : Multi-Function Output (Keep running
without an alarm displayed)
7 : Multi-Function Output Only (detection
working when drive running or not)
b5-12
PID Feedback
Low Detection
Level
Sets the PID feedback level used for
detection. When the PID feedback falls below
this level for longer than the time set to b5-
13, PID feedback loss will be detected.
Default
0%
Min.: 0%
Max.: 100%
b5-13
PID Feedback
Low Detection
Time
Sets the PID feedback time used for
detection. When the PID feedback falls below
the level set to b5-12 for longer than this
time, PID feedback loss will be detected.
Default
1.0 s
Min.: 0.0 s
Max.: 25.5 s
b5-14
PID Sleep Start
Level
Sets the PID level to trigger the drive to sleep.
Default
0.0Hz
Min.: 0.0 Hz
Max.:<5>
b5-15
PID Sleep Delay
Time
Sets the delay time used to
activate/deactivate the PID Sleep function.
When this parameter is set to 0.0, PID Sleep
function will be stopped.
Default
0.0 s
Min.: 0.0 s
Max.: 25.5 s
b5-16
PID Command
Acc./Dec. Time
Sets the PID command acceleration
/deceleration time used for PID target soft-
start function.
Default
0.0 s
Min.: 0.0 s
Max.: 20.0 s
b5-17
PID Target
Selection
0
PID Target Disabled
1
PID Target Enabled
Default
0
Min.: 0
Max.: 1
b5-18
PID Target Value
Sets the PID target value as a percentage of
the maximum output frequency when b5-
17=1 and no other ananlog input sets the PID
Target.
Default
0.00%
Min.: 0.00%
Max.: 100.00%
b5-19
PID Target Value
Units
0
0.01Hz
1
0.01% (Maximum Frequency is 100%)
2
r/min. (Number of Motor Poles must be
set)
3
User Defined (Defined by b5-24 and b5-
25)
Default
1
Min.: 0
Max.: 3
b5-20
PID Output
Lower Limit
Sets the lower limit as a percentage of the
maximum output frequency set in d1-02 for
PID output.
Default
0.0%
Min.: -100.0%
Max.: 100.0%