EasyManuals Logo

LMI Technologies Gocator 2180 User Manual

Default Icon
652 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #394 background imageLoading...
Page #394 background image
Gocator Line Profile Sensors: User Manual
Gocator Device Files • 395
Element Type Description
0 – U-shape
1 – V-shape
2 – Open
MinDepth 64f Minimum depth.
MinWidth 64f Minimum width.
MaxWidth 64f Maximum width.
RegionEnabled Bool Whether or not to use the region. If the region is disabled,
all available data is used.
Region
ProfileRegion2d
Measurement region.
Measurements\X Groove tool
measurement
X measurement.
Measurements\Z Groove tool
measurement
Z measurement.
Measurements\Width Groove tool
measurement
Width measurement.
Measurements\Depth Groove tool
measurement
Depth measurement.
Element Type Description
@id 32s Measurement ID. Optional (measurement disabled if not
set).
Name String Measurement name.
Enabled Boolean
Measurement enable state:
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
PreserveInvalidsEnabled Boolean Preserve invalid measurements enable state
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
Groove Tool Measurement

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2180 and is the answer not in the manual?

LMI Technologies Gocator 2180 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2180
CategoryAccessories
LanguageEnglish