Protocols 503
Indicator ID Instance Value
Digital Output Fail 21007 Output Index Number of fail digital output pulse.
Trigger Drops** 21010 Number of dropped triggers. The sum of various
triggering-related drop indicators.
Output Drops** 21011 Number of dropped output data. The sum of all
output drops (analog, digital, serial, host server,
and ASCII server).
Host Server Drops** 21012 The number of bytes dropped by the host data
server. Not currently emitted.
ASCII Server Drops** 21013 The number of bytes dropped by the ASCII
Ethernet data server. Not currently emitted.
Controlled Trigger Drops 21017 Trigger drops from the Controlled Triggering
System (Grouped with “Trigger Drops” indicator)
Surface Processing Time 21018 Processing Time of Frame on 35XX/32XX
(microseconds)
Max Frame Rate 21019 Max Configurable frame rate given above
Processing Time (scaled by 1x10-6)
Range Valid Count** 21100 - Number of valid ranges.
Range Invalid Count** 21101 - Number of invalid ranges.
Anchor Invalid Count** 21200 - Number of frames with anchoring invalid.
First Log Id 21301 ID of the first available log entry.
Last Log Id 21300 ID of the last available log entry. It is inclusive: for
example, if first = 3 and last = 5, the available log
IDs are 3, 4, 5. If no log is available, the last ID is less
than the first ID.
Z-Index Drop Count 22000 - The number of dropped surfaces due to a lack of z-
encoder pulse during rotational part detection.
Value 30000 Measurement ID Measurement Value.
Pass 30001 Measurement ID Number of pass decision.
Fail 30002 Measurement ID Number of fail decision.
Max 30003 Measurement ID Maximum measurement value.
Min 30004 Measurement ID Minimum measurement value.
Average 30005 Measurement ID Average measurement value.
Std. Dev. 30006 Measurement ID Measurement value standard deviation.
Invalid Count 30007 Measurement ID Number of invalid values.
Overflow 30008 Measurement ID
Number of times this measurement has overflown
on any output. Multiple simultaneous overflows
result in only a single increment to this counter.
Overflow conditions include:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2180 and is the answer not in the manual?

LMI Technologies Gocator 2180 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2180
CategoryAccessories
LanguageEnglish

Related product manuals