3 Technical Data
3.3 Other Data
Weight 7.5 kg
Operation Temperature: +10 °C to +40 °C (+50 °F to +104 °F)
Storage Temperature -10 °C to +60 °C (+14 °F to +140 °F)
Continuous noise level < 65 dB(A)
3.4 Safety Device
Over-pressure safety
(rupture disc)
min. 9 bar (130 PSI); max. 12.5 bar (174 PSI)
Tightening torque of the rupture disc max. 20 Nm
4 Installation
4.1 Environmental and Operating Conditions
– Keep the pressure hose as short as possible. Short switch-on and switch-off times for the
dispensing valve are within reach.
– Keep product feed lines as short as possible. The shorter the feedline the smaller the specific
resistance and the lower the dispensing pressure can be. Avoid kinking.
– In any cases, the pressure hose and product feedline should not be longer than 2 m.
– Do not use inflexible hoses and feed lines, so that unnecessary loads on the fittings will be
avoided.
– Keep all fittings tight.
– No direct sunlight; no UV light.
– No condensing humidity.
– No splash water.