Guide for troubleshooting for PS2 pump controller
Version: V210126
6.10. How to check the isolation of the motor
Different to the motor phase measurement it is important to use an isolation test device. This
device can measure the resistance at a high voltage level.
Configure your isolation measuring
device:
o Choose isolation
measurement at 1000V
o Test prods into its provided
sockets (black to COM & red
to Ω)
The measurement is easier and safer
by using those crocodile clips
Connect the measuring clips to the
motor phases (3 different steps L1
to GND, L2 to GND and L3 to GND)
The value should not be below 0,5 M.