Page 22
Lotus Service Notes Section EMR
Disable Criteria:
• None
Malfunction Criteria:
• Signalvoltage>4.765V
Potential failure modes:
• Signalopencircuit
• Referencevoltageopencircuit
• Referencevoltageshorttoground
• Sensorfailure
Diagnostic Mask:
• TheMILwillbeilluminatediffaultispresent.
P0222
Monitor:
• Continuous.
Enable Criteria:
• None
Disable Criteria:
• None
Malfunction Criteria:
• Signalvoltage<2.146V
Potential failure modes:
• Signalshortcircuit
• Referencevoltageopencircuit
• Referencevoltageshorttoground
• Sensorfailure
Diagnostic Mask:
• TheMILwillbeilluminatediffaultispresent.
Notes: A maximum throttle opening of 15% may be imposed due to this single code. In the case of multiple
codes, a mechanically sprung 7% opening may be applied.
P0223
Monitor:
• Continuous.
Enable Criteria:
• None
Disable Criteria:
• None
Malfunction Criteria:
• Signalvoltage>4.985V
2009/02