Chapter 2 Specifications
2-9
1) How to install terminating resistor
Be sure to install the terminating resistor on the both ends of the line.
(Rnet I/F module and last slave node)
Connect Rnet I/F module with TRX2+ and TRX2- and Smart I/O Rnet module with TRX2+ and TRX2-.
Resistance value: 110, 1/2W, allowance 5%
Contact between connector case and terminating resistor is not allowed.
2) How to install terminating resistor when using repeater module in a network with a repeater,
the terminating resistor is divided into trunk line and branch lines.
Terminating resistor shall be installed at both ends of the trunk.
Install a terminating resistor only at the slave end of the repeater branch (L1 to L8 port).
(Terminating resistors are built in the repeater's slave ports (L1 to L8).)
2.4 Terminating resistor
Smart I/O/Repeater connection area
Rnet I/F connection area
Terminating resistor
Terminating resistor