EasyManua.ls Logo

LS Industrial Systems GLOFA GM7U Series - Main Unit (NPN TR Output)

LS Industrial Systems GLOFA GM7U Series
367 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6. Input and Output Specifications
6-10
6.3.2 Main unit (NPN TR output)
1) Specifications
Main Unit
Model
Specifications
G7M-DRT20U(N)(/DC)
G7M-DT20U(N)(/DC)
G7M-DRT30U(N)(/DC)
G7M-DT30U(N)(/DC)
G7M-DRT40U(N)(/DC)
G7M-DT40U(N)(/DC)
G7M-DRT60U(N)(/DC)
G7M-DT60U(N)(/DC)
Output point 4 points ( 8 points) 4 points (12 points) 4 points (16 points) 4 points (24 points)
Insulation method Photo coupler insulation
Rated load voltage DC12/24V
Operation load voltage DC10.2 ~ 26.4V
Max. load current
0.5A/point (but, QX0.0.0, QX0.0.1 : 0.1A)
Surge absorber Zener diode
Off leakage current Less than 0.1mA
Voltage drop when on Less than DC 0.3 V (0.1A)
Inrush current Less than 4A, 10ms
Off On 0.2 ms or lower Response
time
On Off 0.2 ms or lower
Operation indicator LED is on at on status of output
1) 4 points of QX0.0.0~QX0.0.3 are for positioning function in G7M-DRT(DT)20/30/40/60U(N)(/DC). They also can be used
for general TR output.
2) Do not use for AC load, or they can be destroyed.
REMARK
P/C
R2
R
3
24V
TR1
QX0.0.2 , QX0.0.3
Internal
Circuit
R2
R
24V
TR
Internal
circuit
QX0.0.0 , QX0.0.1

Table of Contents