Chapter 7. Usage of Various Functions
7-42
7.2 Special Modules
The special module and allocated data registers are as follow.
Item
Combination module
A/D
Conversion
module
D/A
Conversion
module
Analog
timer
RTD input
module
Data
Register
Expansion
G7F-ADHA G7F-ADHB
G7F-ADHC
G7F-AD2A
G7F-AD2B
G7F-DA2I
G7F-DA2V
G7F-AT2A G7F-RD2A
%MW4100
CH0
A/D value
CH0
A/D value
CH0
A/D value
CH0
A/D value
CH0
D/A value
CH0
A/T value
(%MW4160)
CH0
Temperature
value
%MW4101
CH1
A/D value
CH1
A/D value
-
CH1
A/D value
CH1
D/A value
CH1
A/T value
(%MW4161)
CH1
Temperature
value
%MW4102
CH0
D/A value
CH0
D/A value
CH0
D/A value
CH2
A/D value
CH2
D/A value
CH2
A/T value
(%MW4162)
CH2
Temperature
value
%MW4103
Analog
module
#1
-
CH1
D/A value
-
CH3
A/D value
CH3
D/A value
CH3
A/T value
(%MW4163)
CH3
Temperature
value
%MW4104
CH0
A/D value
CH0
A/D value
CH0
A/D value
CH0
A/D value
CH0
D/A value
CH0
A/T value
(%MW4164)
CH0
Temperature
value
%MW4105
CH1
A/D value
CH1
A/D value
-
CH1
A/D value
CH1
D/A value
CH1
A/T value
(%MW4165)
CH1
Temperature
value
%MW4106
CH0
D/A value
CH0
D/A value
CH0
D/A value
CH2
A/D value
CH2
D/A value
CH2
A/T value
(%MW4166)
CH2
Temperature
value
%MW4107
Analog
module
#2
-
CH1
D/A value
-
CH3
A/D value
CH3
D/A value
CH3
A/T value
(%MW4167)
CH3
Temperature
value
%MW4108
CH0
A/D value
CH0
A/D value
CH0
A/D value
CH0
A/D value
CH0
D/A value
CH0
A/T value
(%MW4168)
CH0
Temperature
value
%MW4109
CH1
A/D value
CH1
A/D value
-
CH1
A/D value
CH1
D/A value
CH1
A/T value
(%MW4169)
CH1
Temperature
value
%MW4110
CH0
D/A value
CH0
D/A value
CH0
D/A value
CH2
A/D value
CH2
D/A value
CH2
A/T value
(%MW4170)
CH2
Temperature
value
%MW4111
Analog
module
#3
-
CH1
D/A value
-
CH3
A/D value
CH3
D/A value
CH3
A/T value
(%MW4171)
CH3
Temperature
value
RTD input module stores the temperature value and the digital conversion value of temperature in a range of 0 to 4000.
Digital conversion value Temperature value
Expansion
Ch 0 Ch 1 Ch 2 Ch 3 Ch 0 Ch 1 Ch 2 Ch 3
#1 %MW4100 %MW4101 %MW4102
%MW4103
%MW4120
%MW4121
%MW4122 %MW4123
#2 %MW4104 %MW4105 %MW4106
%MW4007
%MW4124
%MW4125
%MW4126 %MW4127
#3 %MW4108 %MW4109 %MW4110
%MW4011
%MW4128
%MW4129
%MW4130 %MW4131
REMARK
1) Offset/gain value can’t be changed, it is fixed.
2) Analog inputting is set the current since this is manufactured.
3) Max. of 3 expansion modules can be used.