Chapter 7. Usage of Various Functions
7-97
(3) JOG speed
(A) JOG High Speed
JOG high speed operation has operation pattern as acceleration, constant speed, deceleration section. Therefore,
acceleration section and deceleration section is controlled by JOG acceleration/deceleration time.
JOG high speed setting range : 5 100,000(unit: 1pps)
(notices when setting the high speed : Bias speed Jog high speed Speed limit)
(B) JOG Low Speed
JOG low speed operation has only constant speed operation pattern.
JOG low speed setting range : 5 100,000 (unit: 1pps)
2) Positioning parameter