EasyManua.ls Logo

LS Industrial Systems XGB Series - Transmission Specifications; Cable Specifications; Cable Classification

LS Industrial Systems XGB Series
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Specifications
8
2.2 Transmission Specifications
[Table 2-2] shows transmission specifications of XGB Fast Enet I/F module media.
Item Specifications Remark
Transmission speed
Auto/10M/100Mbps -
Transmission type
Base band -
Flow control
HALF/FULL -
Modulation Type
NRZI 4B/5B coding
Transformer CT
1:1 Node-Hub
Max. distance between nodes
100m -
Max. segment length
- -
Max. number of nodes
Hub connection -
Nod interval
- -
Max. protocol size
Data 512bite -
Communication zone access
method
CSMA/CD -
Transmissio
n
specification
s
Check method of frame error
CRC32 -
[Table 2-2] Transmission specifications
2.3 Cable Specifications
2.3.1 Cable classification
XGB Fast Enet I/F module takes UTP cable which is over Cat 5. [Table 2-3] shows cable specifications.
Classification Details Purpose
UTP(or U.UTP)
So called unshielded cable used for
HS signal
Max. 200MHz
Phonetic + Data + low grade of video signal
FTP(or S.UTP)
Cable with cable core only shielded
solely
Max.100MHz
Electronic impediment (EMI) and electric stability
considered
Phonetic + Data + low grade of video signal(
STP(or S.STP)
Double-shielded structure, pair
shielded and core shielded cable
Max. 500MHz
Phonetic + Data + Video signal
Substitute for 75 coaxial cable
[Table 2-3] Cable class
Remark
1) XGB Fast Enet I/F module does not support AUI (10BASE-5).
2) Twisted paired cable unit (above category 5) takes 100Mbps class hub and if network speed is 10 Mbps, it
can be used with 10Mbps class hub (below category 3). Make sure this to install system.

Table of Contents