6  Measurement Output 
Measurements are transmitted in accordance with UMB binary protocol (Factory Settings). 
You can find an example of a measurement request in different protocols and a complete 
summary of the list of channels in the Appendix. 
6.1  Air and Dewpoint Temperature 
Sampling rate    1 minute 
Generation of average value  1 – 10 minutes 
Units    °C; °F 
Request channels: 
Measurement Variable (float) 
6.2  Wind Chill Temperature 
Sampling rate    1 minute, computed on base of the average temperature  
    and average wind speed 
Units    °C; °F 
Request channels: 
Measurement Variable (float) 
6.3  Humidity 
Sampling rate    1 minute 
Generation of average value  1 – 10 minutes 
Units    %RH; g/m³; g/kg 
Request channels: 
Measurement Variable (float) 
6.4  Air Pressure 
Sampling rate    1 minute 
Generation of average value  1 – 10 minutes 
Unit    hPa 
Request channels: 
Measurement Variable (float) 
 
Note: For the correct calculation of relative air pressure, the altitude of the location must be 
entered in the device configuration (see Figure 11 on page 28). The factory setting for 
altitude is 0m; in this way both measurement variables deliver the same values.