Operating Manual    Compact Weather Station 
36  G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany   
 
 
 
 
13.1  Measuring Range / Accuracy 
13.1.1  Air temperature 
Measurement process:  NTC 
Measuring range:  -50°C ... +60°C 
Resolution:  0.1°C(-20°C...+50°C), otherwise 0.2°C 
Sensor accuracy:  +/- 0.2°C (-20°C ... +50°C), otherwise +/-0.5°C (>-30°C) 
Sampling rate:  1 minute 
Units:  °C; °F 
13.1.2  Humidity 
Measurement process:  Capacitive 
Measuring range:  0 ... 100% RH 
Resolution:  0.1% RH 
Accuracy:  +/- 2% RH 
Sampling rate:  1 minute 
Units:  % RH; g/m³; g/kg 
13.1.3  Dewpoint Temperature 
Measurement process:  Passive, calculated from temperature and humidity 
Measuring range:  -50°C ... +60°C 
Resolution:  0.1°C 
Accuracy:  Computed +/- 0.7°C 
Units:  °C; °F 
13.1.4  Air Pressure 
Measurement process:  MEMS sensor - capacitive 
Measuring range:  300 ... 1200hPa 
Resolution:  0.1hPa 
Accuracy:  +/- 1.5hPa 
Sampling rate:  1 minute 
Unit:  hPa 
13.1.5  Wind Speed 
Measurement process:  Ultrasound 
Measuring range:  0 … 60m/s 
Resolution:  0.1m/s 
Accuracy:  ±0.3 m/s or ±3% (0...35 m/s) 
  ±5% (>35m/s) RMSE 
Response threshold:  0.3 m/s 
Sampling rate:  10 seconds / 1 second with restrictions 
Units:  m/s; km/h; mph; kts 
13.1.6  Wind Direction 
Measurement process:  Ultrasound 
Measuring range:  0 – 359.9° 
Resolution:  0.1° 
Accuracy:  < 3° RMSE from 1.0 m/s 
Response threshold:  0.3 m/s 
Sampling rate:  10 seconds / 1 second with restrictions 
13.1.7  Precipitation 
Measurement process:  Radar sensor 
Measuring range (drop size):  0.3 mm ... 5.0 mm 
Liquid precipitation resolution:  0.01 mm 
Precipitation types:  Rain, snow 
Repeatability:  Typically > 90% 
Response threshold:  0.01 mm 
Sampling rate:  Event-dependent on reaching response threshold